data.edit.corr.neph_trunc
data.edit.corr.neph_trunc applies the truncation correction described in Anderson and Ogren (1998) to TSI neph data.
data.edit.corr.neph_trunc can operate as either an independent filter (provided the correct input is given) or as part of the correction chain
Command Line Usage
data.edit.corr.neph_trunc [--input=S11] [--maxgap=time] [--smooth=TC] [--cut=1/10]
Arguments
--input=S11
Specify what instrument or record base to use as the input, instead of trying to match what's available. Required if the input stream is ambiguous.
--maxgap=time
Set maximum data gap in seconds before the smoothers are cleared.
--smooth=TC
Set the time constant to smooth with. Zero disables smoothing. Default is a time constant of three.
--cut=1/10
Force the cut size to 1 or 10 um and ignore the flags defining it.
Example Usage
data.get sgp S11a 2008:10 2008:11 | data.edit.corr.neph_trunc